Detección intraoperatoria de hipoxia cerebral isquémica mediante sensores de presión tisular de oxígeno
Intraoperative detection of ischemic brain hypoxia using oxygen tissue pressure microprobes
J. Ibáñez
, J. Vilalta, T. Topczewski, J. Sahuquillo, E. Rubio
Servicio de Neurocirugía. Hospital Universitario Vall d’Hebron. Universidad Autónoma. Barcelona
A. Vilalta*, M.P. Mena*, M. Noguer**
* Unidad de Neurotraumatología, Institut de Recerca Vall d’Hebron.
** Servicio de Anestesiología y Reanimación. Hospital Universitario Vall d’Hebron. Universidad Autónoma. Barcelona
Article information
Abstract
Bibliography
Download PDF
Statistics
Resumen
Objetivo e Importancia

La detección de los eventos isquémicos intraoperatorios puede contribuir a la resolución de su causa y a la prevención del establecimiento definitivo de un infarto postquirúrgico. Queremos ilustrar las posibilidades que ofrece la monitorización intraoperatoria de la presión tisular de oxígeno (PtiO2) en áreas críticas durante un procedimiento neuroquirúrgico vascular, resaltando su fiabilidad e inmediatez en la obtención de información sobre el estado de oxigenación tisular como marcador de isquemia del territorio vascular expuesto a riesgo.

Presentación clínica

Presentamos el caso de un varón de 32 años con una malformación arteriovenosa (MAV) profunda situada en la región insular. El paciente había sido tratado inicialmente mediante radiocirugía sin resultado satisfactorio.

Intervención

La exéresis de la MAV se realizó a través de un abordaje transilviano transinsular. La PtiO2 se monitorizó en el polo temporal (área de referencia) y en la región temporal posterior (área de riesgo). Ambas mantuvieron niveles de oxigenación tisular parejos hasta la fase final de la resección de la MAV en la que, durante la hemostasia de un supuesto vaso aferente, se produjo una brusca caída de la tensión de oxígeno en la región temporal posterior. En el postoperatorio se observó un infarto isquémico en este área.

Conclusión

La monitorización de la PtiO2 tiene una alta fiabilidad en la detección de hipoxia tisular intraoperatoria. Los datos que nos proporciona pueden servir para identificar precozmente estos acontecimientos y, en la medida de lo posible, solventar la situación creada para prevenir la instauración definitiva de un infarto isquémico.

Palabras clave:
Monitorización intraoperatoria
Isquemia cerebral
Presión tisular de oxígeno
PtiO2
Neurocirugía vascular
Summary
Objective and Importance

Detection of intraoperative ischemic events could lead to the resolution of their cause and to the prevention of the definitive establish-ment of a postoperative infarct. We want to illustrate the possibilities that intraoperative monitoring of oxygen tissue pressure (PtiO2) in critical areas during a neurosurgical vascular procedure offers, enhancing its reliability and immediacy in obtaining information about tissue oxygenation status as a marker of ischemia in the vascular territory at risk.

Clinical presentation

We report the case of a 32 years-old male with a deep arteriovenous malforma-tion (AVM) localised in the insular region. The patient had been previously treated with radiosurgery without achieving a satisfactory result.

Intervention

AVM removal was performed through a transylvian transinsular approach. PtiO2 was monitorised at the temporal pole (reference area) and at the posterior temporal region (risk area). Both probes maintained close tissue oxygenation levels until the last stage of the AVM resection when, during the coagula-tion of a supposed afferent vessel, a brisk fall of the oxygen tissue pressure in the posterior temporal region was detected. An ischemic infarct in this area was observed postoperatively.

Conclusions

PtiO2 monitoring has a high reliability in the detection of intraoperative tissue hypoxia. Data obtained could lead to early identification of these events and, whatever possible, to resolve this situation preventing the definitive establishment of an ischemic infarct.

Key words:
Intraoperative monitoring
Brain ischemia
Oxygen tissue pressure
PtiO2
Vascular neurosurgery

Article

These are the options to access the full texts of the publication Neurocirugía (English edition)
Member
Member of the Sociedad Española de Neurocirugía

If it is the first time you have accessed you can obtain your credentials by contacting Elsevier Spain in suscripciones@elsevier.com or by calling our Customer Service at902 88 87 40 if you are calling from Spain or at +34 932 418 800 (from 9 to 18h., GMT + 1) if you are calling outside of Spain.

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option ¿I have forgotten my password¿.

Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Neurocirugía (English edition)

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
Email
Idiomas
Neurocirugía (English edition)
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?