array:23 [ "pii" => "S1130147306703165" "issn" => "11301473" "doi" => "10.1016/S1130-1473(06)70316-5" "estado" => "S300" "fechaPublicacion" => "2006-01-01" "aid" => "70316" "copyright" => "Sociedad Española de Neurocirugía" "copyrightAnyo" => "2006" "documento" => "article" "crossmark" => 0 "subdocumento" => "fla" "cita" => "Neurocirugia. 2006;17:527-31" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 2239 "formatos" => array:3 [ "EPUB" => 19 "HTML" => 1074 "PDF" => 1146 ] ] "itemSiguiente" => array:18 [ "pii" => "S1130147306703177" "issn" => "11301473" "doi" => "10.1016/S1130-1473(06)70317-7" "estado" => "S300" "fechaPublicacion" => "2006-01-01" "aid" => "70317" "copyright" => "Sociedad Española de Neurocirugía" "documento" => "article" "crossmark" => 0 "subdocumento" => "fla" "cita" => "Neurocirugia. 2006;17:532-7" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 1578 "formatos" => array:3 [ "EPUB" => 14 "HTML" => 934 "PDF" => 630 ] ] "es" => array:10 [ "idiomaDefecto" => true "titulo" => "Degeneración tumoral en meningocele no intervenido. Descripción de dos casos" "tienePdf" => "es" "tieneTextoCompleto" => 0 "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "532" "paginaFinal" => "537" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Tumoral degeneration occurring over a non-healing meningocele. Report of two cases" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contienePdf" => array:1 [ "es" => true ] "autores" => array:2 [ 0 => array:2 [ "autoresLista" => "D. Rivero-Celada, L.I. Carcavilla-Loncán, J.M. Cantero-Antón, J. Eiras-Ajuria" "autores" => array:4 [ 0 => array:2 [ "nombre" => "D." "apellidos" => "Rivero-Celada" ] 1 => array:2 [ "nombre" => "L.I." "apellidos" => "Carcavilla-Loncán" ] 2 => array:2 [ "nombre" => "J.M." "apellidos" => "Cantero-Antón" ] 3 => array:2 [ "nombre" => "J." "apellidos" => "Eiras-Ajuria" ] ] ] 1 => array:2 [ "autoresLista" => "M.A. Marín-Cárdenas, J. Alfaro-Torres, F. Duato- Jané" "autores" => array:3 [ 0 => array:2 [ "nombre" => "M.A." "apellidos" => "Marín-Cárdenas" ] 1 => array:2 [ "nombre" => "J." "apellidos" => "Alfaro-Torres" ] 2 => array:2 [ "nombre" => "F." "apellidos" => "Duato- Jané" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1130147306703177?idApp=UINPBA00004B" "url" => "/11301473/0000001700000006/v1_201305151259/S1130147306703177/v1_201305151259/es/main.assets" ] "itemAnterior" => array:18 [ "pii" => "S1130147306703153" "issn" => "11301473" "doi" => "10.1016/S1130-1473(06)70315-3" "estado" => "S300" "fechaPublicacion" => "2006-01-01" "aid" => "70315" "copyright" => "Sociedad Española de Neurocirugía" "documento" => "article" "crossmark" => 0 "subdocumento" => "fla" "cita" => "Neurocirugia. 2006;17:519-26" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 3567 "formatos" => array:3 [ "EPUB" => 21 "HTML" => 2275 "PDF" => 1271 ] ] "es" => array:10 [ "idiomaDefecto" => true "titulo" => "Valor predictivo de la clasificación de Knosp en el grado de resección quirúrgica de los macroadenomas invasivos. Estudio prospectivo de una serie de 23 casos" "tienePdf" => "es" "tieneTextoCompleto" => 0 "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "519" "paginaFinal" => "526" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Predicitve value of the Knosp classification in the staging of invasive pituitary macroadenomas. A Prospective study of 23 cases" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contienePdf" => array:1 [ "es" => true ] "autores" => array:2 [ 0 => array:2 [ "autoresLista" => "J. Enseñat, T. Topcewski, J. Vilalta, J. Sahuquillo" "autores" => array:4 [ 0 => array:2 [ "nombre" => "J." "apellidos" => "Enseñat" ] 1 => array:2 [ "nombre" => "T." "apellidos" => "Topcewski" ] 2 => array:2 [ "nombre" => "J." "apellidos" => "Vilalta" ] 3 => array:2 [ "nombre" => "J." "apellidos" => "Sahuquillo" ] ] ] 1 => array:2 [ "autoresLista" => "G. Obiols, J. Mesa, A. Ortega" "autores" => array:3 [ 0 => array:2 [ "nombre" => "G." "apellidos" => "Obiols" ] 1 => array:2 [ "nombre" => "J." "apellidos" => "Mesa" ] 2 => array:2 [ "nombre" => "A." "apellidos" => "Ortega" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1130147306703153?idApp=UINPBA00004B" "url" => "/11301473/0000001700000006/v1_201305151259/S1130147306703153/v1_201305151259/es/main.assets" ] "en" => array:15 [ "idiomaDefecto" => true "titulo" => "Time sparing and effective procedure for dural closure in the posterior fossa using a vicryl mesh (Ethisorb®)" "tieneTextoCompleto" => 0 "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "527" "paginaFinal" => "531" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "I. Reyes-Moreno, R. Verheggen" "autores" => array:2 [ 0 => array:2 [ "nombre" => "I." "apellidos" => "Reyes-Moreno" ] 1 => array:3 [ "nombre" => "R." "apellidos" => "Verheggen" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">¿</span>" "identificador" => "cor0005" ] ] ] ] "afiliaciones" => array:1 [ 0 => array:1 [ "entidad" => "Department of Neurosurgery. University Hospital and School of Medicine. Gottingen. Germany" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "Correspondence to: Department of Neurosurgery. University Hospital and School of Medicine. University of Gottingen. Robert-Koch Str. 40. 37073 Gottingen. Germany." ] ] ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Cierre de duramadre en cirugía de fosa posterior con una malla de vicryl (Ethisorb®): un procedimiento simple y efectivo" ] ] "pdfFichero" => "main.pdf" "tienePdf" => true "fechaRecibido" => "2006-01-26" "fechaAceptado" => "2006-02-19" "PalabrasClave" => array:2 [ "en" => array:2 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Key words" "identificador" => "xpalclavsec159440" "palabras" => array:5 [ 0 => "CSF leaks" 1 => "Dural closure" 2 => "Dural substitutes" 3 => "Posterior fossa surgery" 4 => "Vicryl mesh" ] ] 1 => array:4 [ "clase" => "abr" "titulo" => "Abreviaturas" "identificador" => "xpalclavsec159442" "palabras" => array:2 [ 0 => "CSF" 1 => "LCR" ] ] ] "es" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Palabras clave" "identificador" => "xpalclavsec159441" "palabras" => array:5 [ 0 => "Cierre dural" 1 => "Cirugía de fosa posterior" 2 => "Duramadre" 3 => "Fístulas de LCR" 4 => "Malla de vicryl" ] ] ] ] "tieneResumen" => true "resumen" => array:2 [ "en" => array:2 [ "titulo" => "Summary" "resumen" => "<span class="elsevierStyleSectionTitle">Introduction</span><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">. Dural defects and cerebrospinal fluid (CSF) leaks are a common problem following posterior fossa surgery. The management includes either nonoperative management (e.g. external lumbar drainage) or surgical re-exploration.</p> <span class="elsevierStyleSectionTitle">Objectives</span><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">We present our surgical, clinical and histopathological experience of dural closure in the posterior fossa. In order to avoid CSF leaks we developed a simple but effective and time-sparing method using a well-cut sheet of a vicryl-poly-pdioxanone mesh (Ethisorb ®) covering the whole defect of the craniectomy. Additional fibrin glue or sealant is not necessary. Special attention was focused upon the frequency of postoperative complications, in particular infection rate and CSF leaks.</p> <span class="elsevierStyleSectionTitle">Patients</span><p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">85 patients were treated with vicryl mesh as dural substitute after posterior fossa surgery due to distinct pathologies. An illustrative case is presented.</p> <span class="elsevierStyleSectionTitle">Results</span><p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">In none of the patients a postoperative infection was observed. Four patients presented postoperative CSF leakage and were treated by percutaneous lumbar drainage. Three of the patients improved completely, requiring no additional treatment. Only in one case defect covered by a vicryl mesh, a surgical reexploration became necessary.</p> <span class="elsevierStyleSectionTitle">Conclusion</span><p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">We consider the vicryl mesh (Ethisorb ®) as an ideal dural substitute especially for the dural closure of the posterior fossa.</p>" ] "es" => array:2 [ "titulo" => "Resumen" "resumen" => "<span class="elsevierStyleSectionTitle">Introducción</span><p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">Los defectos en el cierre de duramadre y por consiguiente fístulas de líquido cefalorraquídeo son comunes en cirugía de fosa posterior. El tratamiento incluye manejo conservador o no quirúrgico como drenaje lumbar externo de líquido cefalorraquídeo, cuando éstas medidas fallan se requiere de una nueva cirugía.</p> <span class="elsevierStyleSectionTitle">Objetivos</span><p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">Con el propósito de evitar fístulas de líquido cefalorraquídeo en cirugía de fosa posterior desarrollamos un método simple, pero efectivo, que permite ahorrar tiempo quirúrgico utilizando una malla de viyril-poly-p-dioxanone (Ethisorb®) para cubrir por completo el defecto de la craniectomía. No se requiere del uso adicional de adhesivo de fibrina. Nuestra experiencia clínica, quirúrgica y hallazgos histopatológicos con ésta técnica de cierre dural se discuten en el presente artículo así como las complicaciones, en particular infección y presencia de fístulas de líquido cefalorraquídeo.</p> <span class="elsevierStyleSectionTitle">Pacientes</span><p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">En 85 pacientes sometidos a cirugía de fosa posterior debida a diferentes patologías, se utilizó una malla de vicryl (Ethisorb®) como sustituto de duramadre. Se presenta un caso que ilustra nuestra técnica.</p> <span class="elsevierStyleSectionTitle">Resultados</span><p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">En ninguno de los casos se presentó infección postoperatoria. Cuatro casos presentaron fístula de líquido cefalorraquídeo y fueron tratados con drenaje lumbar externo; tres pacientes mejoraron por completo sin requerir otras medidas. Sólo en un caso se requirió de exploración quirúrgica.</p> <span class="elsevierStyleSectionTitle">Conclusiones</span><p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">De acuerdo con los resultados y complicaciones, consideramos que la malla de vicryl (Ethisorb®) es un sustituto de duramadre ideal, en particular para cirugías de fosa posterior.</p>" ] ] "NotaPie" => array:1 [ 0 => array:2 [ "etiqueta" => "☆" "nota" => "<p class="elsevierStyleNotepara">Reyes-Moreno, I.; Verheggen, R.: Time sparing and effective procedure for dural closure in the posterior fossa using a vicryl mesh (Ethisorb®). Neurocirugía 2006; 17: 527–531.</p>" ] ] "bibliografia" => array:2 [ "titulo" => "References" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0005" "bibliografiaReferencia" => array:27 [ 0 => array:3 [ "identificador" => "bib1" "etiqueta" => "1." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Epylepsy from cortical cicatrix: trephining; subdural implantation of rubber tissue" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "R. Abbe" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Ann Surg" "fecha" => "1897" "volumen" => "25" "paginaInicial" => "95" "paginaFinal" => "96" ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib2" "etiqueta" => "2." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Gold foil in cerebral surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "H.H.A. Beach" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Boston Med Surg J" "fecha" => "1897" "volumen" => "136" "paginaInicial" => "281" "paginaFinal" => "282" ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib3" "etiqueta" => "3." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Unusual complications with use of Silastic dura substitute" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "T. Banerjee" 1 => "J.N. Meagher" 2 => "W.E. Hunt" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Am Surg" "fecha" => "1983" "volumen" => "40" "paginaInicial" => "434" "paginaFinal" => "437" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/4835017" "web" => "Medline" ] ] ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib4" "etiqueta" => "4." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Evaluation of dural closure techniques. Suture methods, fibrin adhesive sealant, and cyanoacrylate polymer" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "J.E. Cain" 1 => "R.F. Dryer" 2 => "B.R. Barton" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Spine" "fecha" => "1988" "volumen" => "13" "paginaInicial" => "720" "paginaFinal" => "725" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/2461598" "web" => "Medline" ] ] ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib5" "etiqueta" => "5." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Clinical use of freeze-dried human dura mater" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "J.B. Campbell" 1 => "C.A.L. Bassett" 2 => "J.W. Robertson" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3171/jns.1958.15.2.0207" "Revista" => array:6 [ "tituloSerie" => "J Neurosurg" "fecha" => "1958" "volumen" => "15" "paginaInicial" => "207" "paginaFinal" => "214" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/13514521" "web" => "Medline" ] ] ] ] ] ] ] ] 5 => array:3 [ "identificador" => "bib6" "etiqueta" => "6." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Inflammatory reaction to synthetic dura substitute" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "A.R. Cohen" 1 => "S. Aleksic" 2 => "J. Ransohoff" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3171/jns.1989.70.4.0633" "Revista" => array:6 [ "tituloSerie" => "J Neurosurg" "fecha" => "1989" "volumen" => "70" "paginaInicial" => "633" "paginaFinal" => "635" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/2926503" "web" => "Medline" ] ] ] ] ] ] ] ] 6 => array:3 [ "identificador" => "bib7" "etiqueta" => "7." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Vicral (Polyglactin 910) Synthetic absorbable sutures" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "J. Conn" 1 => "R. Oyasu" 2 => "M. Welsh" 3 => "J.M. Beal" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Am J Surg" "fecha" => "1974" "volumen" => "128" "paginaInicial" => "19" "paginaFinal" => "23" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/4275878" "web" => "Medline" ] ] ] ] ] ] ] ] 7 => array:3 [ "identificador" => "bib8" "etiqueta" => "8." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Complications to the use of vicryl-collagen dural substitute" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "G. Gudmundson" 1 => "I. Sogaard" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Acta Neurochir (Wien)" "fecha" => "1995" "volumen" => "132" "paginaInicial" => "145" "paginaFinal" => "147" ] ] ] ] ] ] 8 => array:3 [ "identificador" => "bib9" "etiqueta" => "9." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Freeze-dried cadaveric dural grafts can stimulate a damaging response in the host" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "M.H. Johnson" 1 => "E.J. Thompson" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Eur Neurol" "fecha" => "1981" "volumen" => "20" "paginaInicial" => "445" "paginaFinal" => "447" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/7308245" "web" => "Medline" ] ] ] ] ] ] ] ] 9 => array:3 [ "identificador" => "bib10" "etiqueta" => "10." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Creutzfeldt-Jacob disease in a pregnant woman with an implanted dura mater graft" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "K.L. Lane" 1 => "O. Brown" 2 => "D.N. Howell" 3 => "B.J. Crain" 4 => "C.M. Hulette" 5 => "P.C. Burger" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Neurosurgery" "fecha" => "1994" "volumen" => "34" "paginaInicial" => "737" "paginaFinal" => "740" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8008176" "web" => "Medline" ] ] ] ] ] ] ] ] 10 => array:3 [ "identificador" => "bib11" "etiqueta" => "11." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Vicryl (Polyglactin 910) mesh as a dural substitute" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "P.K. Maurer" 1 => "J.V. Mc Donald" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3171/jns.1985.63.3.0448" "Revista" => array:6 [ "tituloSerie" => "J Neurosurg" "fecha" => "1985" "volumen" => "63" "paginaInicial" => "448" "paginaFinal" => "452" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/4020473" "web" => "Medline" ] ] ] ] ] ] ] ] 11 => array:3 [ "identificador" => "bib12" "etiqueta" => "12." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Collagen vicryl – a new dural prothesis" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "N. Meddings" 1 => "R. Scott" 2 => "R. Bullock" 3 => "D.A. French" 4 => "T.A. Hide" 5 => "S.D. Gorham" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Acta Neurochir (Wien)" "fecha" => "1992" "volumen" => "117" "paginaInicial" => "53" "paginaFinal" => "58" ] ] ] ] ] ] 12 => array:3 [ "identificador" => "bib13" "etiqueta" => "13." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Vicryl (Polyglactin 910) mesh as a dural substitute in the presence of pia aracnoid injury" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "C.E. Nussbaum" 1 => "P.K. Maurer" 2 => "J.V. McDonald" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3171/jns.1989.71.1.0124" "Revista" => array:6 [ "tituloSerie" => "J Neurosurg" "fecha" => "1989" "volumen" => "71" "paginaInicial" => "124" "paginaFinal" => "127" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/2738630" "web" => "Medline" ] ] ] ] ] ] ] ] 13 => array:3 [ "identificador" => "bib14" "etiqueta" => "14." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Use of Vicryl (polyglactin 910) mesh to limit epidural scar formation after laminectomy" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "C.E. Nussbaum" 1 => "J.V. McDonald" 2 => "R.B. Baggs" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Neurosurg" "fecha" => "1990" "volumen" => "26" "paginaInicial" => "649" "paginaFinal" => "654" ] ] ] ] ] ] 14 => array:3 [ "identificador" => "bib15" "etiqueta" => "15." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Complication of silastic dural substitute 20 years after dural plasty" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "N. Ohbayashi" 1 => "T. Inawaga" 2 => "Y. Katoh" 3 => "K. Kumano" 4 => "R. Nagasako" 5 => "H. Hada" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Surg Neurol" "fecha" => "1994" "volumen" => "41" "paginaInicial" => "338" "paginaFinal" => "341" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8165508" "web" => "Medline" ] ] ] ] ] ] ] ] 15 => array:3 [ "identificador" => "bib16" "etiqueta" => "16." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Use of porcine dermis as a dural substitute in 72 patients" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "P. O’Neill" 1 => "A.E. Booth" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3171/jns.1984.61.2.0351" "Revista" => array:6 [ "tituloSerie" => "J Neurosurg" "fecha" => "1984" "volumen" => "61" "paginaInicial" => "351" "paginaFinal" => "354" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/6737060" "web" => "Medline" ] ] ] ] ] ] ] ] 16 => array:3 [ "identificador" => "bib17" "etiqueta" => "17." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "An unusual complication of dura film as dural substitute" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "C.M. Ongkiko" 1 => "J.T. Keller" 2 => "F.H. Mayfield" 3 => "S.B. Dunsker" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3171/jns.1984.60.5.1076" "Revista" => array:6 [ "tituloSerie" => "J Neurosurg" "fecha" => "1984" "volumen" => "60" "paginaInicial" => "1076" "paginaFinal" => "1079" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/6232353" "web" => "Medline" ] ] ] ] ] ] ] ] 17 => array:3 [ "identificador" => "bib18" "etiqueta" => "18." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Jacob-Creutzfeldt disease associated with cadaveric dura" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "P.L. Penar" 1 => "J.W. Prichard" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "J Neurosurg" "fecha" => "1987" "volumen" => "67" "paginaInicial" => "149" "paginaFinal" => "150" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/3298564" "web" => "Medline" ] ] ] ] ] ] ] ] 18 => array:3 [ "identificador" => "bib19" "etiqueta" => "19." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Meningocerebral adhesions. An experimental study of the effect of human amniotic membrane, amnioplastin, beef allantoic membrane, Cargile membrane, tantalum foil and polyvinyl alcohol films" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "R.H. Pudenz" 1 => "G.L. Odom" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Surgery" "fecha" => "1942" "volumen" => "12" "paginaInicial" => "318" "paginaFinal" => "344" ] ] ] ] ] ] 19 => array:3 [ "identificador" => "bib20" "etiqueta" => "20." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The use of tantalum foil in the subdural space" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "R.C.L. Robertson" 1 => "W.G. Peacher" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "J Neurosurg" "fecha" => "1948" "volumen" => "2" "paginaInicial" => "281" "paginaFinal" => "284" ] ] ] ] ] ] 20 => array:3 [ "identificador" => "bib21" "etiqueta" => "21." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Experimental evaluation of collagen- coated vicryl mesh as a dural substitute" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "F. San-Galli" 1 => "V. Darrouzet" 2 => "J. Rivel" 3 => "C. Baquey" 4 => "D. Ducassou" 5 => "J. Guérrin" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Neurosurgery" "fecha" => "1992" "volumen" => "30" "paginaInicial" => "396" "paginaFinal" => "401" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/1620304" "web" => "Medline" ] ] ] ] ] ] ] ] 21 => array:3 [ "identificador" => "bib22" "etiqueta" => "22." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Lyophilized human dura mater as a dural substitute" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "P.C. Sharkey" 1 => "F.C. Usher" 2 => "R.C.L. Robertson" 3 => "C. Pollard" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3171/jns.1958.15.2.0192" "Revista" => array:6 [ "tituloSerie" => "J Neurosurg" "fecha" => "1958" "volumen" => "15" "paginaInicial" => "192" "paginaFinal" => "198" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/13514519" "web" => "Medline" ] ] ] ] ] ] ] ] 22 => array:3 [ "identificador" => "bib23" "etiqueta" => "23." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Fascia lata graft as dural substitute in neurosurgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "K.V. Thammavaran" 1 => "E.C. Benzel" 2 => "L. Kesterson" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "South Med J" "fecha" => "1990" "volumen" => "83" "paginaInicial" => "634" "paginaFinal" => "636" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/2356495" "web" => "Medline" ] ] ] ] ] ] ] ] 23 => array:3 [ "identificador" => "bib24" "etiqueta" => "24." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "A new technique of dural closure – experience with a vicryl mesh" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:7 [ 0 => "R. Verheggen" 1 => "J. Schulte-Baumann" 2 => "G. Hahm" 3 => "J. Lang" 4 => "S. Freudenthaler" 5 => "Th. Schaake" 6 => "E. Markakis" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Acta Neurochir (Wien)" "fecha" => "1997" "volumen" => "139" "paginaInicial" => "1074" "paginaFinal" => "1079" ] ] ] ] ] ] 24 => array:3 [ "identificador" => "bib25" "etiqueta" => "25." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The repair of dural defects by graft. An analysis of 540 penetrating wounds of the brain incurred in the Korean War" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "P.B. Wallace" 1 => "A.M. Meirowsky" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Ann Surg" "fecha" => "1960" "volumen" => "151" "paginaInicial" => "174" "paginaFinal" => "180" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/13842598" "web" => "Medline" ] ] ] ] ] ] ] ] 25 => array:3 [ "identificador" => "bib26" "etiqueta" => "26." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Creutzfeldt-Jakob disease transmitted by a cadaveric dura mater graft" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "S. Yamada" 1 => "T. Aiba" 2 => "Y. Endo" 3 => "M. Hara" 4 => "T. Kitamoto" 5 => "J. Tateishi" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Neurosurgery" "fecha" => "1994" "volumen" => "34" "paginaInicial" => "740" "paginaFinal" => "744" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8008177" "web" => "Medline" ] ] ] ] ] ] ] ] 26 => array:3 [ "identificador" => "bib27" "etiqueta" => "27." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Lymphocytic meningitis following insertion of a porcine dermis dural graft" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "A.Z. Zeman" 1 => "R.S. Maurice-Williams" 2 => "R. Luxton" 3 => "A. Levene" 4 => "E.J. Thompson" 5 => "P. Harvey" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Surg Neurol" "fecha" => "1993" "volumen" => "40" "paginaInicial" => "75" "paginaFinal" => "80" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8322186" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "en" "url" => "/11301473/0000001700000006/v1_201305151259/S1130147306703165/v1_201305151259/en/main.assets" "Apartado" => null "PDF" => "https://static.elsevier.es/multimedia/11301473/0000001700000006/v1_201305151259/S1130147306703165/v1_201305151259/en/main.pdf?idApp=UINPBA00004B&text.app=https://revistaneurocirugia.com/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1130147306703165?idApp=UINPBA00004B" ]
Información de la revista
Compartir
Descargar PDF
Más opciones de artículo
Time sparing and effective procedure for dural closure in the posterior fossa using a vicryl mesh (Ethisorb®)
Cierre de duramadre en cirugía de fosa posterior con una malla de vicryl (Ethisorb®): un procedimiento simple y efectivo
I. Reyes-Moreno, R. Verheggen
Department of Neurosurgery. University Hospital and School of Medicine. Gottingen. Germany